WHERE TO GET THE INTERNAL FUSE:
http://search.digikey.com/scripts/DkSearch/dksus.dll?lang=en&site=US&WT.z_homepage_link=hp_go_button&KeyWords=f2318-nd
The G540 is limited to 50V and 3.5A. This does not mean that it CANNOT run larger motors--just that this will limit the performance of larger motors.
A motor that draws over 3.5A will have its torque detuned. A motor that needs more than the 50V will detune from top speed.
Keling 1200s:
KL34H2120-60-4A:
78V 6A. = fairly fast speed & detuned 700oz torque with G540. Could be geared down 0.6 :1 to increase torque back to 1200 oz.
KL34H2120-42-8A:
PARALLEL: 82V 6A = Medium speed, 700oz torque.
SERIES: 163V 3A = Very slow speed, 1200 oz torque.
Keling 906:
KL34H-295-43-8A:
Parallel: 58V, 6.1A = Fast speed, detunes to 522oz torque.
Series: 116V, 3.1A = Slow speed, 906 oz torque.
Keling 640:
KL34H280-45-8A
Parallel: 48V, 6.3A = Very fast speed, detunes to 356 oz torque.
Series: 95V 3.2A = Slow speed, 640 oz torque.
HOW TO DOWNLOAD THE G540B.xml FILE:
1. Go to Geckodrive.com
2. Left click products
3. Left click G540
4. Find G540 software configuration XML and right click on it.
5. Left click save target as.
6. Left click My Recent Documents
7. Scroll to find Mach3 and right click on it. (It might be in MY DOCUMENTS also)
8. Left click SELECT
9. Left click SAVE
10. Right click START
11. Left click Explore
12. Left click Mach3
13. Scroll down to bottom and see if 540B.xml is there.
CR.